Wood-gasifiction boilers (HV)

BACK

wood gasification boiler with forced draught fan

The KÜNZEL wood-gasifying boiler is a special burner for chopped wood of any kind - from course cuttings to logs of over 0.5 m in length. The KÜNZEL HV uses approx. 1/3 less fuel than conventional wood burning systems..

Although the KÜNZEL wood-gasifying boiler is a boiler with “bottom burn-off”, the concept is a completely new one. A temperature-controlled forced draught fan is located at the front, behind the panel between the door through which the wood is loaded and the door through which the ash is removed. On demand, the exact amount of combustion air is delivered as primary and secondary air. This process enables the output efficiency to rise as high as 90%, meaning that pollutant emission stays well below the legal limits.

KÜNZEL wood-gasification boilers have been thoroughly tested by the relevant government authorities. They fully comply with the clean-air regulations under the Law Concerning the Protection against Harmful Effects on the Environment (BImSchV) and are certified to the relevant standards.

holzvergaser_heizkessel_gasification_boiler

The HV 24 - including microprocessor control panel


Typ HV 15 24 35 50
Nominal output wood kW 14,9 18 – 26 28 – 40 40 – 50
Volume of filling space Liter 88 116 155 210
Depth of filling space mm 400 550 600 600
Dimensions of filling door W x H mm 380 x 255 380 x 255 450 x 300 450 x 350
Exhaust flow rate (when replenishing)

kg/Sek.

0,011 (0,023) 0,015 (0,030) 0,023 (0,045) 0,030 (0,060)
Draught requirement Pa min. 10 bis 18
Water content Liter 53 75 106 150
Air fan Watt 35 35 50 50
A - Width mm 560 560 650 680
B - Depth mm 720 870 930 1000
C - Height mm 1240 1240 1400 1630
D - Height of exhaust connection mm 1060 1060 1190 1430
Ø Flue gas connection mm 150 180 180 200
Weight kg 235 300 380 415

technical specifications are subject to change without notice