| Boiler Hercules BIOMASS in
cast iron allows effective
and ecological exploitation of cheap fuel like wooden waste, wood chips and
saw-dust in an automatic operation. |
|

Hercules Biomass Boilers from 7-48kW
This
biomass boiler enables effective and ecological use of wood waste. Its operation
is automated and requires minimum handling. The 5-section version of
the boiler is designed for heating single housing units and smaller
facilities of up to*250sqm area. The 7-section version of the boiler is
designed for heating houses, cottages, office buildings and small business
premises etc of up to *350sqm area. The 10-section version of the boiler
is designed for heating middle-sized buildings: shops, schools, recreation
facilities, middle-sized business premises, big houses etc for up to
*500sqm area.
*Note:
based on pre 2003 building standards.
Area
can greatly differ due to insulation standards and heating systems of the
building. |
Hercules BIOMASS boiler advantages
 |
Automatic operation controlled by room's control unit. |
 |
Mechanical fuel transport from
build-on silo to burner |
 |
For
all your heating and hot water |
 |
User friendly
low in maintenance |
 |
Low heating costs |
 |
Low
running cost |
 |
Forced
fuel gases ventilation |
 |
High lifetime of cast-iron boiler body |
 |
Variable boiler lay-out depending on boiler-room
area |
 |
Well tested boiler body construction, high efficiency
up to 83% |
Hercules BIOMASS technical data
|
| Number of sections |
ks |
5 |
7 |
10 |
| Nominal output |
kW |
20 |
30 |
45 |
| Regulated output |
kW |
6 - 20 |
9 - 30 |
14 - 45 |
| Fuel consumption (humidity 15%, fuel value 18,0 MJ.kg-1) |
kg . h-1 |
2,6 - 6,1 |
2,6 - 8,9 |
4,1 - 13,4 |
| Efficiency |
% |
80 - 83 |
| Consumption gas temperature |
°C |
110 - 200 |
| Boiler class by ČSN EN 303-5 |
- |
3 |
| Weight |
kg |
602 |
694
|
830 |
| Water volume |
dm3 |
40,9 |
50,3 |
64,4 |
| Chimney diameter inside |
mm |
160 |
| Fuel capacity |
dm3 |
1190 |
| Max. water overpressure |
bar |
4 |
| Testing water overpressure |
bar |
8 |
| Recommended working temperature of heating water |
°C |
65 – 80 |
| Boiler's hydraulic loss |
mbar |
0,6 |
1,4 |
2,8 |
| Chimney draught |
mbar |
0,2 – 0,35 |
| Boiler connection - heating / return water |
mm |
70 |
| electric connection |
- |
3/N/PE AC ~ 50 Hz 400/230 V TN
- S |
| Motor's electric power |
W |
960 |
| Electric protection of control unit |
- |
IP 65 |
|
Download
boiler information (pdf)
The boiler is automatically operated and is
controlled by a heat-controller in the house, which ensures comfortable
space heating and hot water.
The fuel, wood chips, shavings and sawdust is mechanical delivered from a
built-on fuel hopper to the burner. The boiler is easy to operate, low in
maintenance and gives a good alternative to standard heating systems due
to the low operating costs and low emissions.
Combustion by-products are easy cleaned out from the ash box and
heat-exchanger. The high lifetime cast-iron drum
(heat exchanger) is available in several layouts depending on the space
available in the boiler room. Long verified design of the boiler drum
guaranties a high combustion
efficiency of up to 80%
|
|