KÜNZEL HV(S) Operating Panel

Standard Control Panel for forced draught fan boiler HV

The standard control is a practical thermostatic control system. It contains a control phase for external switching
as well as following thermostats, switches and lamps:
künzel_standard_controller_panel

1. Boiler thermostat (to set required boiler temperature between 80°C and 90°C)
2. Boiler thermometer to read off current boiler temperature
3. Operating switch, start switch and operating control lamps for start, operation, pump, fan (from left to right)
4. Pump thermostat (pump is not activated until working temperature has been reached)
5. Fan-Stop thermostat (stops the heating operation if boiler is burnt empty or temperature has dropped below a set minimum)

Micro-Processor control panel 911T for forced draught fan boiler HV with two-stage output and buffer storage tank control

With this microprocessor control panel, the boiler can work at two levels of output. If the set temperature, e.g. 80°C, is exceeded, the control panel reduces the fan output to part-load. This lengthens the combustion time and increases the efficiency rating. The control panel includes a buffer storage heater control (difference temperature control) and the possibility of determining the temperature of the buffer storage heater. Switches, illuminated segment indicators and lamps (LEDs) are protected by a smooth front foil. The control panel contains a relay to trigger a reversing valve on automatic switchover to external heating. In addition, there are 8 DIP switches on the back with which, for example, the run-down times for the fan (automatic heat maintenance) or the set temperature can be changed. The individual functions of the control panel are as follows:

kuenzel_micro_processor_control_panel_911_T

1. ON/OFF key for the start-up programme
2. Signal lamp for fan operation (also for fan support when by-pass shutter is open in the heating-up phase)
3. Warning light drawing attention, among other things, to - open by-pass shutter - normal operation not achieved after 57 minutes (start-up failure)
4. Warning light drawing attention to excess temperature (95°C)
5. Luminous indication of boiler temperature
- flashing malfunction indication when there are faults
- indicates temperature of upper part of buffer storage tank (at the same time hot water supply tank) and of lower part, as well as the average temperature on request
- reduced operation indicated by light in the bottom right-hand corner.

 

6. Touch controls to set desired boiler temperature between 80°C and 90°C in 1°C steps.
7. Lamp indicating external oil/gas heating operation (if existing).

8. Touch control to determine storage tank temperatures
9. Differential-temperature adjustment between boiler and buffer storage tank, the buffer storage tank is only charged when the boiler temperature is higher than the storage tank temperature.
10. Signal lamp for boiler pump (pump is switched off at 68°C and starts up again when the boiler temperature exceeds 70°C).
11. Warning light - buffer storage tank charged to 85%, do not add any more wood.

Micro-Processor-panel 911 S – for induced draught fan boiler HV-S

Description see 911 T(above)

technical data subject to alteration